BLASTMATE® SERIES III VIBRATION MONITOR

Seismic Range 254 mm/s
Resolution 0.127 mm/s, 0.0159 mm/s with built-in preamp.
Trigger Levels 0.127 to 254 mm/s in steps of 0.01 mm
Frequency Analysis National and Local Standards for all countries
Accuracy 3% at 15 Hz.
Acceleration, Displacement calculated using entire waveform, not estimated at peak.
Air Linear Range 88-148 dB (500 pa peak).
Resolution 0.1 dB above 120 dB steps.
Trigger Levels 100-148 dB in 1 dB steps.
Accuracy 0.2 dB at 30 Hertz and 127 dB.
A weight (optional) Range 50 to 110 dB in steps of 0.1 dB.
Sampling Rate Standard 1024 samples per second per channel to 16,384 (8,192 for 8 channel)
Event Storage Full Waveform events 300 standard, 900 and 1500 optional at standard sample rate of 1024.
Summary Events 1750 stabdard, 5250 and 8750 optional at standard sample rates of 1024.
Frequency Response 2 to 300 Hz Ground and air, independent of record time.
Full Waveform Recording Fixed Record Modes Manual, single shot, continuous and programmed start/stop.
Fixed Record Time 1 to 100, 300 or 500 sec plus 0.25 sec pretrigger.
Auto Record Mode 1 to 100, 300 or 500 sec plus 0.25 sec pretrigger.
Strip Chart Recording Record Method Record to memory and/or internal printer. Program interval 5, 15, 60 or 300 sec.
Days Storage 3, 9 or 15 days at 5 second interval. 34, 107 or 180 days at 5 minute interval.
Special Functions Timer Operation Programmed start/stop.
Self Check Programmable daily check.
Scaled Distance Weight and distance stored with event.
Monitor Log History printout programmable up to all events stored.
Meausrement Units Imperial or metric, dB or linear air pressure, or in units of custom sensors.
Location Log GPS (Global Positioning System) data into record.
Printer Resolution 576 dots/line and 0.125mm per dot.
Print Time Less than 10 seconds for typical 1 second event with full analysis.
Paper Control Paper tear slot or automatic paper takeup, separate keys for feed and takeup.
Rated Life - print head 30km of printing
Number of Copies 1 to 10 copies automatic, any number manual.
User Interface Keyboard 64 domed tactile with separate keys for common features.
Display 4 line by 20 characters high contrast backlit display with on line help.
Battery Life MiniMate Plus 10 days continuous recording, 25 days with timer.
BlastMate 30 days continuous recording, 70 days with timer, printing will decrease life.
Dimensions MiniMate Plus (81 mm x 91 mm x 160 mm
BlastMate 269 mm x 355 mm x 165 mm
Weight MiniMate Plus 1.4 kg
BlastMate 6.4 kg
Warranty 2 years parts and labour Calibration and equipment check required at 1 year to maintain warranty.
Environmental Printer/LCD -10 to 50 degrees C operating.
Electronics -20 to 60 degrees C operating
Storage -20 to +70 degrees C


Call GISCO / 1-800-523-1526 (952-929-8000)
FAX 952-926-5498 / EMAIL:sales@giscogeo.com

left  BACK TO VIBRATION INDEX